ANT-52 is a high-performance in-line linear actuator with a max load capacity of 6000N.
Featuring a sleek design, high load capacity, IP67M waterproof protection, and synchronous operation, the ANT-52 is perfect for outdoor applications where the actuator will be visible.
Ideal for skylights, smoke vent systems, yacht automation, and agricultural machinery applications.
Features and options
| Max Load in push(N) | 6000N |
| Max Loadin pull(N) | 6000N |
| Voltage(V) | 12V/24V |
| No-load current(A) | ≤1.6A/≤0.8A |
| Load current(A) | ≤10A/≤5A |
| Max.Power(W) | 120W |
| Material ofouter tube | 6063Aluminium/316stainlesssteel |
| Material oflead screw | Trapezoid steel |
| Materialof piston rod | 316 stainless steel |
| Material ofthe nut | Engineering plastic |
| Protection Class | IP66/IP67M/IP69K |
| Noise on load (dB) | ≤75dB |
| Backlash(mm) | 0.5-1mm |
| Colour | Black/Silver |
| Strokelength(mm) | ≤500mm |
| Limit switch | Built-in |
| Options | Over current protection/Hall sensor/Limit switch signal line output |
| Standard cable length(m) | 1.5m (cable length can be customized) |
Forces and speeds
| Push force【N】 | Pull force【N】 | Self-locking force【N】 | Speed on load【mm/s】 | No load speed【mm/s】 |
| 300 | 300 | 600 | 50 | 88 |
| 1200 | 1200 | 2400 | 13 | 24 |
| 1800 | 1800 | 3600 | 9.5 | 16 |
| 3000 | 3000 | 6000 | 5.5 | 9.6 |
| 4500 | 4500 | 8000 | 3.5 | 6.4 |
| 5000 | 5000 | 7500 | 2.8 | 4.8 |
| 6000 | 6000 | 8000 | 2.5 | 4.8 |
Stroke and Weight
| Stroke【mm】 | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 |
| AL Weight【kg】 | 1.8 | 1.9 | 2 | 2.1 | 2.2 | 2.3 | 2.4 | 2.5 |
| S/SWeight【kg】 | 3.95 | 4.15 | 4.35 | 4.55 | 4.75 | 4.95 | 5.15 | 5.35 |
Usage
| Operating temperature(℃) | -20℃~60℃ |
| Storage temperature(℃) | -40℃~70℃ |
| Working duty(S2) | 10%, 2 minutes continuous use followed by 18 minutesin rest |
| Life time(cycles) | ≥10000 cycles |
| Certification | CE/RoHS |


Built-in dimensions
| Option | Minimum BID[mm] | A |
| Standard | 305+stroke length | 201 |
| IP67M/IP69K | 325+stroke length | 221 |
| Hall sensor | 325+stroke length | 221 |
| Over current protection | 325+stroke length | 221 |
| Signal line output | 325+stroke length | 221 |
Notes: For any special installation size needs, please contact us.
Over current protection
Hall sensor
Limit switch signal line output
Cable lengths
Other stroke lengths available
Customized front, rear fixture
Installation size
Available in all RAL colours